<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">pmj</journal-id><journal-title-group><journal-title xml:lang="ru">Тихоокеанский медицинский журнал</journal-title><trans-title-group xml:lang="en"><trans-title>Pacific Medical Journal</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1609-1175</issn><publisher><publisher-name>TGMU</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.17238/PmJ1609-1175.2017.2.53-55</article-id><article-id custom-type="elpub" pub-id-type="custom">pmj-140</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОРИГИНАЛЬНЫЕ ИССЛЕДОВАНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ORIGINAL RESEARCHES</subject></subj-group></article-categories><title-group><article-title>Сравнение результатов биометрии глаза при использовании различных приборов</article-title><trans-title-group xml:lang="en"><trans-title>Comparison of the results of the eye biometrics using different instruments</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Куликов</surname><given-names>А. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Kulikov</surname><given-names>A. N.</given-names></name></name-alternatives><email xlink:type="simple">alexey.kulikov@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Кокарева</surname><given-names>Е. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Kokareva</surname><given-names>E. V.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Котова</surname><given-names>Н. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Kotova</surname><given-names>N. A.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Военно-медицинская академия им. С.М. Кирова</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Military and Medical Academy named after S.M. Kirov</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2017</year></pub-date><pub-date pub-type="epub"><day>28</day><month>06</month><year>2017</year></pub-date><volume>0</volume><issue>2</issue><fpage>53</fpage><lpage>54</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Куликов А.Н., Кокарева Е.В., Котова Н.А., 2017</copyright-statement><copyright-year>2017</copyright-year><copyright-holder xml:lang="ru">Куликов А.Н., Кокарева Е.В., Котова Н.А.</copyright-holder><copyright-holder xml:lang="en">Kulikov A.N., Kokareva E.V., Kotova N.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.tmj-vgmu.ru/jour/article/view/140">https://www.tmj-vgmu.ru/jour/article/view/140</self-uri><abstract><p>Сравнивались результаты измерений параметров глаза на приборах Lenstar LS900, lOLMaster, Pentacam HR и OPD-Scan II. В исследовании участвовало 50 пациентов (54 глаза). С целью расчета оптической силы интраокулярной линзы выполнена биометрия на указанных приборах со статистической обработкой полученных данных. Между основными параметрами, определенными с помощью приборов Lenstar LS900 и IOLMaster, продемонстрирована высокая зависимость и повторяемость результатов. Данные кератометрии на Pentacam HR в зонах диаметра зрачка и 3 мм и на OPD-Scan II в комбинации с результатами, полученными на Lenstar LS900 и IOLMaster, из-за значимых различий могут быть полезными для выявления более точных вариантов расчета интраокулярных линз.</p></abstract><trans-abstract xml:lang="en"><p>Objective. Comparison of the measurements results of the eye parameters were conducted on the following instruments Lenstar LS900, IOLMaster, Pentacam HR and OPD-Scan II. Methods. The study involved 50 patients (54 eyes). For the purpose of calculating the optical power of the intraocular lens, biometry was performed on these instruments with statistical processing of the obtained data. Results. When measuring the anteroposterior axis and the depth of the anterior chamber of the eye, no clinically and statistically significant difference was obtained by all instruments. A statistically significant difference was found when comparing keratometry on the Lenstar LS900 biometer and Pentacam HR and OPD-Scan II keratotopographs. Conclusios. Between the main parameters of the eye, determined with the Lenstar LS900 and IOLMaster, there is a high dependence and repeatability of the results. The depth of the anterior chamber of the eye, measured with instruments of different types, in formulas for calculating the optical strength of intraocular lenses (Haigis, Holladay, Barret, Olsen) can be used to obtain new calculation algorithms. The keratometric data on Pentacam HR in the pupillary and 3 mm pupil zones and on OPD-Scan II in combination with the results obtained with the Lenstar LS900 and IOLMaster, because of significant differences, may be useful for identifying more accurate variants of intraocular lenses.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>IOLMaster</kwd><kwd>Lenstar LS900</kwd><kwd>Pentacam HR</kwd><kwd>OPD-Scan II</kwd><kwd>IOLMaster</kwd><kwd>Lenstar LS900</kwd><kwd>Pentacam HR</kwd><kwd>OPD-Scan II</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Балашевич Л.И., Качанов А.Б. Клиническая корнеотопография и аберрометрия. М., 2008. 167 с.</mixed-citation><mixed-citation xml:lang="en">Балашевич Л.И., Качанов А.Б. Клиническая корнеотопография и аберрометрия. М., 2008. 167 с.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Стебнев С.Д., Складчикова Н.И. Эффективность использования оптического биометра «LENSTAR LS900, HaagStreit» в достижении «рефракции цели» при имплантации интраокулярных линз «премиум-класса» фирмы Alcon // Современные технологии в офтальмологии. 2014. № 3. С. 89.</mixed-citation><mixed-citation xml:lang="en">Стебнев С.Д., Складчикова Н.И. Эффективность использования оптического биометра «LENSTAR LS900, HaagStreit» в достижении «рефракции цели» при имплантации интраокулярных линз «премиум-класса» фирмы Alcon // Современные технологии в офтальмологии. 2014. № 3. С. 89.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Drexler W., Findl O., Menapace R. [et al.]. Partial coherence interferometry: A novel approach to biometry in cataract surgery // Am. J. Ophthalmol. 1998. Vol. 126. P. 524-534.</mixed-citation><mixed-citation xml:lang="en">Drexler W., Findl O., Menapace R. [et al.]. Partial coherence interferometry: A novel approach to biometry in cataract surgery // Am. J. Ophthalmol. 1998. Vol. 126. P. 524-534.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Gale R.P., Saldana M., Johnston R.L. [et al.]. Benchmark standards for refractive outcomes after NHS cataract surgery // Eye. 2009. Vol. 23. P. 149-152.</mixed-citation><mixed-citation xml:lang="en">Gale R.P., Saldana M., Johnston R.L. [et al.]. Benchmark standards for refractive outcomes after NHS cataract surgery // Eye. 2009. Vol. 23. P. 149-152.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Goebels S, Pattmöller M, Eppig T. [et al.]. Comparison of 3 biometry devices in cataract patients // J. Cataract Refract. Surg. 2015. Vol. 41, No. 11. P. 2387-2393.</mixed-citation><mixed-citation xml:lang="en">Goebels S, Pattmöller M, Eppig T. [et al.]. Comparison of 3 biometry devices in cataract patients // J. Cataract Refract. Surg. 2015. Vol. 41, No. 11. P. 2387-2393.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Güler E., Kulak A.E., Totan Y. [et al.]. Comparison of a new optical biometry with an optical low-coherence reflectometry for ocular biometry // Cont. Lens Anterior Eye. 2016. URL: http://sci-hub. bz/10.1016/j.clae.2016.06.001 (дата обращения: 30.11.2016).</mixed-citation><mixed-citation xml:lang="en">Güler E., Kulak A.E., Totan Y. [et al.]. Comparison of a new optical biometry with an optical low-coherence reflectometry for ocular biometry // Cont. Lens Anterior Eye. 2016. URL: http://sci-hub. bz/10.1016/j.clae.2016.06.001 (дата обращения: 30.11.2016).</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Li J., Chen H., Savini G. [et al.]. Measurement agreement between a new biometer based on partial coherence interferometry and a validated biometer based on optical low-coherence reflectometry // J. Cataract Refract. Surg. 2016. Vol. 42. P. 68-75.</mixed-citation><mixed-citation xml:lang="en">Li J., Chen H., Savini G. [et al.]. Measurement agreement between a new biometer based on partial coherence interferometry and a validated biometer based on optical low-coherence reflectometry // J. Cataract Refract. Surg. 2016. Vol. 42. P. 68-75.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Olsen T. On the calculation of power from curvature of the cornea // Br. J. Ophthalmol. 1986. Vol. 70. P. 152-154.</mixed-citation><mixed-citation xml:lang="en">Olsen T. On the calculation of power from curvature of the cornea // Br. J. Ophthalmol. 1986. Vol. 70. P. 152-154.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Olsen T. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster // Acta Ophthalmol. Scand. 2007. Vol. 85. P. 84-87.</mixed-citation><mixed-citation xml:lang="en">Olsen T. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster // Acta Ophthalmol. Scand. 2007. Vol. 85. P. 84-87.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Shin M.C., Chung S.Y., Hwang H.S. [et al.]. Comparison of two optical biometres // Optometry and Vision Science. 2016. Vol. 93, No. 3. P. 259-265.</mixed-citation><mixed-citation xml:lang="en">Shin M.C., Chung S.Y., Hwang H.S. [et al.]. Comparison of two optical biometres // Optometry and Vision Science. 2016. Vol. 93, No. 3. P. 259-265.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
