Comparative characteristics of pachymetry methods of anterior segment of eye

Abstract

Was compared accuracy of measurement of corneal thickness by the methods of optical coherence tomography, anterior segment analyze and ultrasonic pachymetry. Was demonstrated difference on data, received by different methods of research according coordinates of research. Accuracy of pachimetry in center spot and oriented by the optical axis raise as follow: anterior segment analyze - ultrasonic pachymetry - optical coherence tomography.

About the Authors

M. E. Nerpina
Clinic of Eye Diseases
Russian Federation


M. D. Pozaritskiy
Institute of Postgraduate Education of Federal Medical-Biological Agency of Russian
Russian Federation


References

1. Bechmann M., Thiel M.J., Roesen B. [et al.] Central corneal thickness measurement with a retinal optical coherence tomography device versus standart ultrasonic pachymetry // Cornea. 2001. Vol. 20. P. 50-54.

2. Chen S., Huang J., Wen D. [et al.] Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry // Acta Ophthalmol. 2012. Vol. 90, No. 5. P. 449-455.

3. Giasson C., Forthomme D. Comparison of central corneal thickness measurements between optical and ultrasound pachymeters // Optom. Vis. Sci. 1992. Vol. 69, P. 236-241.

4. Krachmer J.H., Mark J.M., Edward J.H. Corneа. Elsevier, 2011. 2080 p.

5. Marsich M.M., Bullimore M.A. The repeatability of corneal thickness measures // Cornea. 2000. Vol. 19. P. 792-795.

6. Reinstein D.Z., Silverman R.H., Trokel S.L., Coleman D.J. Corneal pachymetric topography // Ophthalmology. 1994. Vol. 101. P. 432-438.

7. Rainer G., Findl O., Petternel V. Central corneal thickness measurement with partial coherence interferometry, ultrasound, and the Orbscan system // Ophthalmology. 2004. Vol. 111. P. 875-879.

8. Tam E.S., Rootman D.S. Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy // J. Cataract. Refract. Surg. 2003. Vol. 29, No. 6. P. 1179-1184.

9. Wilson R. Corneal pachymetric mapping in normal eyes // Approach. Ophthalmol. 1999. Vol. 11. P. 733-758.


Review

For citations:


Nerpina M.E., Pozaritskiy M.D. Comparative characteristics of pachymetry methods of anterior segment of eye. Pacific Medical Journal. 2014;(4):76-77. (In Russ.)

Views: 221


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1609-1175 (Print)