Intraocular toric lens rotational stability improvement

Abstract

Background. PCEM-based intraocular toric lens (IOL) stability improvement was developed and invented in clinical practice: license 2535612, registered in State Registry of Inventions of RF on October 15, 2014. Methods. 86 patients were operated (97 eyes) with corneal astigmatism aged 35-74. In 42 cases IOL were implanted in accordance with the offered invention. Results. During 12 months average rotation angle of IOL implanted according to traditional technology was 2.2±2.0°. In patients operated by offered methods average rotation angle occurred to be much less - 0.8±1.2°. Conclusions. The offered method of toric IOL fixation ensures their stability even with prominent contraction of capsular lens and provides prevention decentered lenses and anterior lens capsule phimosis preserving visual function for a long time.

About the Author

G. A. Fedyashev
Primorsky center of eye microsurgery , Pacific State Medical University
Russian Federation


References

1. Ерошевская Е.Б. Интраокулярная коррекция афакии у больных первичной открытоугольной глаукомой: дис.. д-ра мед. наук. Самара, 1997. 240 с.

2. Пензева К.В., Тахтаев Ю.В. Анализ толщины сетчатки после выполнения первичного заднего капсулорексиса // Катарактальная и рефракционная хирургия. 2012. Т. 12, № 2. С. 17-20.

3. Федяшев Г. А. Способ повышения ротационной стабильности торических интраокулярных линз: патент RU 2535612 Российская Федерация, МПК A61F 9/00 (№ 2013125066/14, заявл. 29.05.2013, опубл. 20.12.2014. Бюл. № 35).

4. Федяшев Г.А., Егоров В.В., Егорова А.В. Коррекция астигматизма в хирургии катаракты при помощи имплантации торических интраокулярных линз AcrySof toric // Здравоохранение Дальнего Востока. 2010. Т. 46, № 4. С. 46.

5. Chang D. Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses // Journal of Cataract and Refraction Surgery. 2008. Vol. 34. P. 1842-1847.

6. Horn J.D. Status of toric intraocular lenses // Current Opinion in Ophthalmology. 2007. Vol. 18. P. 58-61.

7. Kim M.H, Chung T.Y, Chung E.S. Long-term efficacy and rotational stability of AcrySof toric intraocular lens implantation in cataract surgery // Korean J. Ophthalmol. 2010. Vol. 24. P. 207-212.

8. Rozema J.J., Gobin L., Verbruggen K., Tassignon M.J. Changes in rotation after implantation of a bag-in-the-lens intraocular lens // Journal of Cataract and Refraction Surgery. 2009. Vol. 35, No. 8. P. 1385-1388.

9. Sheppard A.L., Wolffsohn J.S., Bhatt U. [et al.] Clinical outcomes after implantation of a new hydrophobic acrylic toric IOL during routine cataract surgery // J. Cataract. Refract. Surg. 2013. Vol. 39. P. 41-47.

10. Tseng S.S., Ma J.K. Calculating the optimal rotation of a misaligned toric intraocular lens // J. Cataract. Refract. Surg. 2008. Vol. 34. P. 1767-1772.

11. Vickovic I.P, Loncar V.L., Mandić Z. [et al.] Toric intraocular lens implantation for astigmatism correction in cataract surgery // Acta Clin Croat. 2012. Vol. 51. P. 293-297.

12. Visser N., Gast S.T., Bauer N.J. [et al.] Cataract surgery with toric intraocular lens implantation in keratoconus: a case report // Cornea. 2011. Vol. 30. P. 720-723.

13. Visser N., Bauer N.J., Nuijts R.M. Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications // Journal of Cataract and Refraction Surgery. 2013. Vol. 39. P 624-637.

14. Weinand F., Jung A., Stein A. [et al.] Rotation stability of a single-piece hydrophobic acrylic intraocular lens: new method for high-precision rotation control // Journal of Cataract and Refraction Surgery. 2007. Vol. 33, No. 5. P. 800-803.


Review

For citations:


Fedyashev G.A. Intraocular toric lens rotational stability improvement. Pacific Medical Journal. 2015;(3):26-28. (In Russ.)

Views: 252


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1609-1175 (Print)